Place of Origin:
Anhui, China
نام تجاری:
Wayeal
گواهی:
CE
Model Number:
IC6600
Introduction of Ion Chromatography Instrument
The Ion Chromatography Instrument is a state-of-the-art analytical device designed to provide precise and reliable ion separation and quantification for a wide range of applications. The IC6600 series multi-functional ion chromatograph is a high-end ion chromatography system launched by Wayeal. Featuring a brand-new modular design, it offers exceptional flexibility, more comprehensive functionality, and simpler operation. This system can be configured with a conductivity detector, an amperometric detector, or a UV detector to enable the detection of all ion chromatography-related analytes, including conventional anions and cations, cyanide, iodide, sugars, small-molecule organic acids, hexavalent chromium, transition metals, and more.
Technical Parameters of IC6600 Ion Chromatography Instrument
|
Product Name |
Multifunctional Ion Chromatography |
|
Model |
IC6600 |
|
Working power |
220V, 50Hz |
|
Ambient temperature |
10-40°C |
|
Relative humidity |
20-85% |
|
Qualitative repeatability |
≤0.1% |
|
Quantitative repeatability |
≤0.5% |
|
Pump flow rate range |
0.001~12.000mL/min |
|
Pressure resistance of pump head |
0-40MPa |
|
Flow setting error |
<0.1% |
|
Flow stability |
<0.1% |
|
Pressure display accuracy |
0.001MPa |
|
Pressure plusation |
<0.25% |
|
Conductivity detector |
|
|
Baseline noise |
≤0.03%FS |
|
Baseline drift |
≤0.1%FS |
|
Mini detectable concentration (Cl): |
≤0.0001μg/mL |
|
Mini detectable concentration (Li): |
≤0.00005μg/mL |
|
Mini detectable concentration (NO3): |
≤0.001μg/mL |
|
Mini detectable concentration (Na+): |
≤0.001μg/mL |
|
Mini detectable concentration (Ca2+): |
≤0.005μg/mL |
|
Conductivity cell volume |
≤0.4μL |
|
Conductivity detection range |
0-45000μS/cm |
|
Detector resolution |
0.00238nS/cm |
|
Conductivity cell temperature setting error |
±0.01°C |
|
Conductivity cell temperature display resolution |
0.001°C |
|
Conductivity cell temperature control range |
Detector temperature zone temperature +5°C-65°C |
|
Conductivity cell temperature control stability |
0.05°C |
|
Conductivity cell temperature setting value error |
0.1°C/h |
|
Ampere detector |
|
|
Type |
Thin-layer structure, automatic range |
|
Driving voltage range |
-2.0V-2.0V |
|
Drive voltage resolution |
0.001V |
|
Output signal range |
Integral mode: 50pc-200uC DC mode: 1pA-74μA |
|
Noise |
Integration mode<30pC DC mode<5pA, DC mode static noise<1pA |
|
Cell material |
Titanium |
|
Pool volume |
<0.2μL |
|
Maximum pool pressure |
0.7MPa |
|
Minimum detectable concerntration |
I-0.001μg/mL |
|
Minimum detectable concerntration fructose |
0.01μg/mL |
|
UV Detector |
|
|
Wavelength indication error |
0.1nm |
|
Wavelength repeatability |
0.1nm |
|
Mini detectable concentration |
BrO3-0.0005μg/mL |
|
Mini detectable concentration |
CrO42-0.001μg/mL |
|
Qualitative repeatability |
≤0.05% |
|
Quantitative repeatability |
≤0.3% |
|
Suppressor |
|
|
Dead volume |
50μL |
|
Inhibition capacity |
170ueq/min |
|
Pressure resistance |
3MPa |
|
Column oven |
|
|
Temperature range |
Room temperature +5°C~70°C |
|
Temperature control stability |
0.1°C/h |
|
Error of temperature setting value |
0.05°C |
|
Autosampler |
|
|
Number of samples |
≥120 (1.5ml sample bottle) |
|
Temperature |
4~30°C |
|
Linear |
>0.999 |
|
Cross-contamination |
<0.01% |
درخواست خود را به طور مستقیم به ما بفرستید